Power Star Series |
|
Model No. | PS1000 | PS2000 | PS3000 | PS4000 | PS5000 | PS6000 |
|
Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W |
|
AC Input |
|
Waveform | Pure Sine Wave |
|
Voltage | 120VAC/230VAC |
|
Acceptable Voltage | 194-243VAC\164-243VAC(wide mode) |
|
Line Low Transfer | 85V±4%/184(154 wide mode±4%) |
|
Line Low Return | 95V±4%/194(164 wide mode±4%) |
|
Line high Transfer | 135V±4%/253±4% |
|
Line high Return | 127V±4%/243±4% |
|
Frequency | 50Hz or 60Hz (Auto sensing) |
|
Line Low Transfer | 47Hz for 50Hz, 57Hz for 60Hz |
|
Line high Transfer | 55Hz for 50Hz, 65Hz for 60Hz |
|
AC Output |
|
Waveform | Pure Sine Wave(bypass mode sync to input) |
|
Voltage | 120/220/230/240VAC(bypass mode sync to input) |
|
Voltage Regulation | ±10%rms(bypass mode sync to input) |
|
Frequency | 50Hz±0.3Hz(bypass mode sync to input) |
|
Peak Power | 3 times of rating power |
|
Short Circuit Protection | Yes,shutdown after 10ms |
|
Power Factor | 0.9-1.0 |
|
DC Input |
|
Battery Voltage | 12V/24V | 12V/24V/48V | 24V/48V |
|
Minimum Start Voltage | 10V for 12V,20V for 24V,40V for 48V |
|
Low Battery Alarm | 10.5V for 12V,21V for 24V,42V for 48V |
|
Low Battery Transfer | 10V for 12V,20V for 24V,40V for 48V |
|
High Voltage Alarm | 16V for 12V,32V for 24V,64V for 48V |
|
Max Charging Current | 35A/70A |
|
Over Charge Voltage | 15.7V for 12V,31.4V for 24V,62.8V for 48V |
|
Transfer Efficiency |
|
Line Mode | >95% |
|
Battery Mode | >88% |
|
power saver | Available when the load is less than 25 Watts |
|
Indicators |
|
7-LED Display | From the right to the left,LED1 line mode (green lighting),LED2 inverter mode |
|
(green lighting),LED3 charging mode(yellow lighting),LED4 Fully charged |
|
(green lighting),LED5 over heat shutdown(red lighting),LED6 Overloaded |
|
shutdown(red lighting),LED7 Saving Mode(green lighting) |
|
3-LED Display | Charging Mode(green lighting),inverter mode(green lighting), Alarm(red lighting) |
|
Switch selector | Saving Mode is on/off when push the switch forwards/backwards, keeping it horisontal is turning the inverter off. |
|
|
Audible Alarm | Sounding when the heatsink's tem is over 105ºC and shutdown after 30 seconds. |
|
Protections | low battery,over charging,over temp,over load |
|
Communications | RS-232/USB(custom-made) |
|
Enviromental |
|
Operating Environment | 0-40ºC,0-90%RH(non-condensing) |
|
Audible Noise | <60dB |
|
Physical |
|
|
|
|
|
|
|
Net Weight(KG) | 18 | 20 | 22 | 35 | 38 | 40 |
|
Dimension L*W*H(mm) | 442*218*179mm | 598*218*179mm |
|