3phase online UPS power with true galvanic isolation transformer design
Model: Low Frequency Online UPS Legend Strar Series LS33 10K-100K(3Ph in/3Ph out)
Key Features
1:Online double-conversion
2:Remote control management(RS-232)
3:DSP technology guarantees high reliability
4:Parallel operation with up to 4 units (option)
5:True galvanic isolation transformer design
6:Intelligent battery management to prolong battery lifecycle
7:software is optional
8:N+1 Parallel systerm for averaging current (optional)
9:Optional communication inter
10:Redundant fan design and independent ventilation enhance durable operation under harsh environment
11:Advanced network monitor function and support various of operation system
Applications
Data center, Industrial equipment, Financial and Securities, Large Data rooms, cars, boats, trucks,
Postal and Telecommunications, Energy and Electricity, Industrial and Commercial tax affair, etc.
Technical Specification
LS33 Series 10K - 80Kva | ||||||
MODEL | 10K | 20K | 30K | 40K | 60K | 80K |
CAPACITY | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW |
INPUT | ||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||
Acceptable Voltage Range | 305VAC ~ 460VAC | |||||
Frequency | 46-54Hz or 56-64Hz | |||||
INVERTER | ||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||
Precision | Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) | |||||
Frequency | 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz | |||||
Max. Synchronisation Speed | ±1 Hz/s | |||||
Waveform | Pure Sinewave | |||||
Total Harmonic Distortion (THDv) | <2% (Linear Load) <5% (Non-linear Load) | |||||
Phase Displacement | 120º ±1% (balanced load) 120º ±2% (imbalances 50% of the load) | |||||
Dynamic Recovery Time | 1 cycle at 98 % of the static value | |||||
Admissible Overload | 110% for 10min; 150% for 60sec ; >160% for 200ms | |||||
Admissible Crest Factor | 3:1 | |||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | |||||
Imbalance Output Voltage @ 100% Unbalanced Load | <1% | |||||
Current Limit | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit | |||||
STATIC BYPASS | ||||||
Type | Solid state | |||||
Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||
Frequency | 50/60 Hz | |||||
Activation Criterion | Microprocessor control | |||||
Transfer Time | Zero | |||||
Admissible Overload | 150% for 1 hour; 180% for 30sec; >200% for 200ms | |||||
Transfer to Bypass | Immediate, for overloads above 160% | |||||
Retransfer | Automatic after alarm clear | |||||
MAINTENANCE BYPASS | ||||||
Type | Without interruption | |||||
Voltage | 3 x 400V (3Ph + N) | |||||
Frequency | 50/60 Hz | |||||
Overall Efficiency | 90% | 91% | 92% | 93% | ||
90% | 91% | 93% | 93% | |||
BATTERY & CHARGER | ||||||
Battery Type and Numbers | 12VDC x 16 pcs | 12VDC x 32 pcs (29~32 pcs adjustable) | ||||
Nominal Battery Voltage | 192 VDC | 384 VDC (Based on 32pcs batteries) | ||||
Charging Method | CC/CV | |||||
Precision | ±1% | |||||
Charging Current | Max.: 40 A | |||||
Charging Voltage | 216 VDC | 432 VDC (Based on 32pcs batteries) | ||||
PHYSICAL | ||||||
Dimensions, D x W x H(mm) | 656 x 405 x 817 | 656 x 405 x 941 | 840 x 432 x 1140 | 975 x 554 x 1286 | ||
Net Weight (Kgs) | 180 | 205 | 295 | 330 | 451 | 519 |
* Product specifications are subject to change without further notice |