upsen holding company limite
|
Price: | 100.0 USD |
Payment Terms: | T/T,L/C,WU,Paypal,Money Gram |
Place of Origin: | Guangdong, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
3kva-5kva High frequency Hybird Inverter with mppt function
Hybird Inverter Charger Empire Star Series 3000W / 5000W (1ph in/1ph out)
Features:
Topology
1>Internal automatic bypass:Yes-TBD
2>Charger:Fly back for 3k, half-bridge for 5k
3>SCC:buck for 3k, interleaved dual buck for 5k(for SCC model only)
4>High frequency push pull converter, and high frequency full bridge Inverter
5>Inverter + SCC(Solar charge controller)(for SCC model only)Pure Sine wave output voltage.
Charger
1)(On/Off controlled by CPU)
2)Three stage charger / ABM
3)Protection against over voltage
4)Charger works even if the input switch is in OFF position, whatever input voltage threshold
MPPT
1:SCC-for SCC model only
2:Microprocessor controlled
3:Three-stage battery charge protection
4:Charger for battery when SCC is available
5:Silent, pulse width modulated (PWM), high efficiency operation
ES Solar Inverter | ||||
Model No. | ES3000 | ES3000S | ES5000 | ES5000S |
CAPACITY | 2.4KW/3000VA | 4.2KW/5000VA | ||
INPUT | ||||
Input Voltage Waveform | Pure Sine Wave (utility or generator ) | |||
Nominal Input Voltage | 230Vac | |||
Input Voltage Range | 170Vac~280Vac(Normal); 90Vac-280Vac(Generator / Wide) | 170Vac~280Vac(Normal); 125Vac-280Vac(Generator / Wide) | ||
Max AC Input Voltage | 300Vac RMS | |||
Nominal Input Frequency | 50Hz / 60Hz(Auto detection) | |||
OUTPUT | ||||
Wave form | Pure sine wave (Inverter mode) | |||
Voltage Regulation (Inverter Mode) | ±10% RMS | |||
Output Frequency | 50Hz / 60Hz ±1Hz | |||
Nominal Efficiency | 90%(@Inverter mode with normal DC Input;>60% R load); 95%(@Inverter mode with Rated R load,battery full charger); | |||
Capable of starting electric motor | 1.5H | 2.5H | ||
Power Factor | 0.8 | 0.84 | ||
Over-Load Protection | Tripped off after 5s@≥150% load Tripped off after 10s@≥110%~150% load | |||
Transfer Time | Normal range:10ms(typical) 15ms(max) Generator / wide renge : 20ms (typical) 40ms(max) | |||
Power Limitation | ||||
BATTERY | ||||
Battery Voltage | 24.0Vdc±0.6Vdc | 48.0Vdc±0.6Vdc | ||
Battery low alarm voltage | 21.0Vdc±0.6Vdc | 42.0Vdc±1.2Vdc | ||
Battery low shut-down voltage | 20.0Vdc±0.6Vdc | 40.0Vdc±1.2Vdc | ||
AC CHARGER | ||||
Charger Current | 10A/20A selectable 10A@Vi/p<170Vac or Vi/p>280Vac; 20A@Vi/p=230Vac | 10A selectable 10A@Vi/p<200Vac or Vi/p>280Vac | ||
Boost Charger Voltage (bat.Type) | 28.4Vdc | 56.8Vdc | ||
Floating Charger Voltage (bat.Type) | 27.4Vdc | 54.8Vdc | ||
Over Charger Voltage | 30.0Vdc | 58.0Vdc | ||
PV CHARGER | ||||
Charger Current | No PV Charger | 40A+5%/-10% | No PV Charger | 60A+5%/-10% |
Bulk Voltage / floating Voltage | 28.4V±0.6V/ 27.4V±0.6V | 56.8V±1.2V/ 54.8V±0.6V | ||
Efficiency | maximum of 95% | maximum of 95% | ||
Input range | 0-75V(±5%) | 0-150V(±5%) | ||
PV charge work range | Bat.V+2V to 75V(±5%) | Bat.V+2V to 150V(±5%) | ||
Storage temperature | -5ºC~60ºC | |||
AUDIBLE ALARM | ||||
Low battery at inverter mode | Beeps 1 time every 2s | |||
Over load | 110%~150% load:beep 10 times every 0.5s >150% load:beep 5 times every 0.5s then fault | |||
Fault | Beeps continuously | |||
PHYSICAL | ||||
Net Weight(KG) | 5.2 | 8.2 | ||
Dimension,D*W*H(mm) | 318*268.4*85.2(mm) | 428.5*350.4*119(mm) | ||
*Specification is subject to change without prior notice. |